CBXVS - AZL20DC-1, SILVER ZINC CELLS/BATTERIES (SUP DAT)

  • MSDS: CBXVS
  • Manufacturer: BST SYSTEMS INC
  • Product Name: AZL20DC-1, SILVER ZINC CELLS/BATTERIES (SUP DAT)
  • National Stock Number: 6135-00N072258
Product Identification

Product ID:AZL20DC-1, SILVER ZINC CELLS/BATTERIES (SUP DAT)
MSDS Date:04/05/1995
FSC:6135
NIIN:00N072258
MSDS Number: CBXVS

Responsible Party
BST SYSTEMS INC
78 PLAINFIELD PIKE RD
PLAINFIELD, CT 06374
US

Emergency Phone: 203-564-4078

Info Phone: 203-564-4078

Cage: 62339

Contractor
BST SYSTEMS INC
PLAINFIELD, CT 06374 US

Telephone: 203-564-4078

Cage: 62339

Ingredients

ZINC OXIDE (SARA 313) (CERCLA)

CAS: 1314-13-2

RTECS: ZH4810000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


LEAD MONOXIDE; (LEAD OXIDE)

CAS: 1317-36-8

RTECS: OG1750000

OSHA PEL 0.05 MG/M3 (MFR)

ACGIH TLV: 0.15 MG/M3 (MFR)


CADMIUM OXIDE (SARA 302/313) (CERCLA)

CAS: 1306-19-0

RTECS: EV1925000

OSHA PEL 0.2 MG (CD)/M3 DUST

ACGIH TLV: 0.01 MG(CD)/M3


SILVER (SARA 313) (CERCLA)

CAS: 7440-22-4

RTECS: VW3500000

OSHA PEL 0.01 MG/M3

ACGIH TLV: 0.1 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


POTASSIUM HYDROXIDE (CERCLA)

CAS: 1310-58-3

RTECS: TT2100000

OSHA PEL C 2 MG/M3

ACGIH TLV: C 2 MG/M3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


POLYSULFONE

CAS: 25154-01-2

OSHA PEL N/K

ACGIH TLV: N/K


ETHYLENE, TETRAFLUORO-, POLYMER; (TEFLON (TAB INSULATORS))

CAS: 116-14-3

RTECS: KX4025000

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE/CHRONIC: CONTACT W/CAUSTIC
LIQUID MAY CAUSE SERIOUS BURNS TO HUMAN TISSUES. OVEREXPOSURE OF
CADMIUM OXIDE MAY CAUSE IRRITATION OF NOSE & THROAT. DELAYED
REACTION OF COUGHING, CHEST PAIN, SWEATIN G, CHILLS, SHORTNESS OF
BREATH & WEAKNESS MAY DEVELOP. IN SEVERE CASES, DEATH MAY OCCUR.
LEAD OXIDE INGEST MAY CAUSE NAUSEA, VOMITING, HEADACHE, DIZZINESS,
GI IRRITATION. CHRONIC EFFECTS RESULTING FRO M LOW LEVEL EXPOSURE
TO LEAD COMPONENTS MAY INCLUDE ANEMIA, KIDNEY DAMAGE, IMPAIRED
EYESIGHT & LEAD BUILDUP IN CNS (PARTICULARLY BRAIN). LEAD APPEARS
ON NAVY LIST OF OCCUPATIONAL CHEMICAL REPRODUCTIVE HAZARDS. SEEK
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:CADMIUM OXIDE: IARC MONOGRAPHS ON
EVALUATION OF CARCINOGENIC RISK OF CHEMICALS TO MAN, VOLUME 58,
PAGE 119, 1993: GROUP 1. NTP 7TH ANNUAL REPORT ON CARCINOGENS,
1994: ANTICIPATED TO BE CARCINOGEN. ANI MAL: LUNG.
Effects of Overexposure:HEALTH HAZARDS: CONSULTATION FROM APPROPRIATE
HEALTH PROFESSIONALS CONCERNING LATEST HAZARD LIST INFORMATION AND
SAFE HANDLING AND EXPOSURE INFORMATION .
Medical Cond Aggravated by Exposure:PREEXISTING KIDNEY, RESPIRATORY,
PROSTATE AND BLOOD SYSTEMS MAY BE AGGRAVATED.

First Aid

First Aid:INHALATION: REMOVE FROM EXPOSURE. GET MEDICAL ATTENTION.
SKIN: REMOVE CONTAMINATED CLOTHING AND WASH WITH LARGE AMOUNTS OF
WATER. GET MEDICAL ATTENTION. EYES: FLUSH WITH WATER FOR AT LEAST
15 MINUTES INCLUDING UNDER THE EYELIDS. GET MEDICAL ATTENTION.
INGESTION: DRINK PLENTY OF WATER AND FRUIT JUICE. DO NOT INDUCE
VOMITING. GET PROMPT MEDICAL ATTENTION.

Fire Fighting

Extinguishing Media:USE EXTINGUISHING MEDIA FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:FIRE MAY LIBERATE TOXIC LEAD & CADMIUM
FUMES AS WELL AS HAZARDOUS FLUORINE COMPONENTS, INCOMPLETE BURNING
OF POLYSULFONE MAY RELEASE CARBON DIOXIDE; THE CONTACT OF KOH (THE
ELECTROLYTE) WITH METALS CA N RELEASE HYDROGEN GAS. ACTIVATED CELLS
OR BATTERIES MAY BE FIRE HAZARD IF EXTERNALLY SHORTED.

Accidental Release

Spill Release Procedures:PROT CLTHG & EQUIP MUST BE WORN BY CLEAN-UP
PERS. CONTAIN SPILLAGE/LEAKAGE IN SUITABLE CONTR/CONTAIN IN HOLDING
AREA. DO NOT ALLOW DRAINAGE TO SEWER, STREAMS/STORM CONDUITS.
REMOVE SOLIDS W/CLEAN SHOV EL & VACUUM LIQ (SUITABLE ABSORB MAY
BEUSED).
Neutralizing Agent:NEUTRALIZE W/WEAK ACID SOLUTION (VINEGAR, BORIC
ACID) & FLUSH W/WATER.

Handling

Handling and Storage Precautions:DRY BATTERIES TO BE STORED AT
TEMPERATURES BETWEEN 0-40F (OPTIMUM).
Other Precautions:WET BATTERIES NOT REQUIRED FOR 30 DAYS OR LONGER
SHOULD BE DISCHARGED AS PER MANUFACTURER'S OPERATING PROCEDURES AND
STORED AT TEMPERATURES BETWEEN 0-40F.

Exposure Controls

Respiratory Protection:USE WITH EFFECTIVE VENTILATION AND WEAR NIOSH
APPROVED FUME RESPIRATOR.
Ventilation:PROVIDE ADEQUATE VENTILATION TO MEET TLV REQUIREMENTS.
LOCAL EXHAUST AND MECHANICAL (GENERAL) VENTILATION ADEQUATE.
Protective Gloves:RUB/PLASTIC-IMPERVIOUS &/WATER PROOF.
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES AND FULL LENGTH
FACESHIELD .
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA . RUBBER OR PLASTIC-IMPERVIOUS AND/OR WATER
PROOF.
Work Hygienic Practices:AVOID DIRECT SKIN CONTACT WITH KOH. TO REDUCE
ELECTROCUTION RISK ALL ASSOCIATED TOOLS SHOULD BE INSULATED.
Supplemental Safety and Health
TRADE NAME/PART #: WITH LEAD AND CADMIUM.

Chemical Properties

Appearance and Odor:CELL-A RECTANGULAR PLASTIC CUBE OF AMBER COLOR WITH
MULTIPLE ELECTRODES VISIBLE

Stability

Stability Indicator/Materials to Avoid:YES
HYDROGEN PEROXIDE, AMINES, REDUCING AGENTS, MOLTEN ALKALI METALS,
ALUMINUM AND TIN (KOH ONLY).
Stability Condition to Avoid:AVOID STORAGE TEMPERATURES GREATER THAN
90F.
Hazardous Decomposition Products:AT TEMPS > 962C/1764F, AG*2O FUME MAY
BE EVOLVED; KOH & METALS MAY LIBERATE H*2 GAS, HYDROGEN FLUORIDE
MAY BE FORMED WHEN TEFLON BURNS.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL LAWS AND REGULATIONS. SPENT (USED) BATTERIES SHOULD BE
COLLECTED FOR PRECIOUS METALS RECLAMATION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.